Sains Malaysiana 43(7)(2014):
1083–1087
Effect
of Scan Rate on Corrosion Inhibition of Carbon Steel in the
Presence
of Rice Straw Extract - Potentiodynamic Studies
(Kesan Kadar Imbasan Terhadap Perencatan Kakisan Keluli Karbon Dalam Kehadiran Ekstrak
Jerami Padi - Kajian Potensiodinamik)
SOLHAN YAHYA,
NORINSAN
KAMIL
OTHMAN*,
ABD
RAZAK
DAUD
& AZMAN
JALAR
School of Applied Physics, Faculty of Science and
Technology, Universiti
Kebangsaan Malaysia
43600 Bangi, Selangor,
Malaysia
Received: 15 March 2013/Accepted: 9 February
2014
ABSTRACT
The effect of scan rate on the accuracy of corrosion parameter in
evaluating the efficiency of rice straw extract as corrosion inhibitor
has been studied via potentiodynamic
polarization measurement. Scan rate in the range of low (0.1-0.25
mV s-1),
medium (0.5-1.0 mV s-1) and high (1.5-2.0 mV s-1)
scan were carried out on the carbon steel in 1 M HCl.
The corrosion parameters such as corrosion rate, polarization resistance
and corrosion current density have been analyzed through Tafel
polarization curve. High scan rate gave poor accuracy of corrosion
parameter compared to medium and low scan. Medium scan at 1.0 mV
s-1
has been chosen as the optimum scan rate due to the
approached steady-state and small disturbance of charged current.
As a result, the addition of rice straw extract in 1 M HCl
has reduced the values of corrosion current density in both cathodic
and anodic reactions signified the corrosion has been inhibited.
The efficiency of rice straw extracts as a corrosion inhibitor offer
good result as much as 86%.
Keywords: Corrosion; potentiodynamic polarization; rice straw extract; scan rate
ABSTRAK
Kesan kadar imbasan ke atas ketepatan parameter kakisan dalam menilai kecekapan perencat kakisan ekstrak jerami padi telah dikaji menerusi ukuran pengutuban potensiodinamik. Penggunaan kadar imbasan pada julat imbasan rendah (0.1-0.25 mV s-1), sederhana (0.5-1.0 mV s-1) dan tinggi (1.5-2.0 mV s-1) telah dilakukan ke atas sampel keluli karbon dalam medium 1 M HCl. Parameter kakisan seperti kadar kakisan, rintangan pengutuban dan ketumpatan arus kakisan telah dianalisis menerusi keluk pengutuban Tafel. Penggunaan kadar imbasan yang tinggi memberikan keputusan parameter kakisan yang kurang tepat berbanding kadar imbasan rendah dan sederhana.
Kadar imbasan sederhana pada 1.0 mV s-1 telah dipilih sebagai kadar imbasan yang optimum berdasarkan keadaan-mantap yang telah tercapai dan gangguan kecil pada arus tercas. Keputusan menunjukkan penambahan ekstrak jerami padi di dalam 1 M HCl telah menurunkan nilai ketumpatan arus kakisan di kedua-dua tindak balas katodik dan anodik menandakan kakisan telah direncatkan. Kecekapan ekstrak jerami padi sebagai perencat kakisan memberikan keputusan yang baik sebanyak 86%.
Kata kunci: Ekstrak jerami padi; kadar imbasan; kakisan; pengutuban potensi dinamik
REFERENCES
Abd El Rehim, S.S., Hassan, H.H. & Amin, M.A. 2001. Corrosion inhibition of aluminum by 1,1(lauryl amido)propyl ammonium chloride in HCl solution. Materials
Chemistry and Physics 70: 64-72.
Atashin, S., Pakshir,
M. & Yazdani, A. 2011. Synergistic investigation into the marine parameters’ effect on the
corrosion rate of AISI 316 stainless steel. Materials and Design 32:
1315-1324.
Bard, A.J. & Faulkner, L.R. 2001. Electrochemical
Methods- Fundamental and Application. New York: Wiley.
Chou, W.J., Yu, G.P. &
Huang, J.H. 2003. Corrosion resistance of ZrN films on AISI 304 stainless steel substrate. Surface
and Coatings Technology 167: 59-67.
El-Etre,
A.Y. 2003. Inhibition of aluminium corrosion using Opuntia extract. Corrosion Science 45: 2485-2495.
Galal, A., Atta, N.F. &
Al-Hassan, M.H.S. 2005. Effect
of some thiophene derivatives on the electrochemical
behavior of AISI 316 austenitic stainless steel in acidic solutions containing
chloride ions I. Molecular structure and inhibition efficiency relationship. Materials
Chemistry and Physics 89: 38-48.
Khaled, K.F. & Abdel-Rehim,
S.S. 2011. Electrochemical investigation of corrosion and
corrosion inhibition of iron in hydrochloric acid solutions. Arabian
Journal of Chemistry 4: 397-402.
Oguzie, E.E., Enenebeaku,
C.K., Akalezi, C.O., Okoro,
S.C., Ayuk, A.A. & Ejike,
E.N. 2010. Adsorption and
corrosion-inhibiting effect of Dacryodis edulisextract on low-carbon-steel corrosion in acidic
media. Journal of Colloid and Interface Science 349: 283-292.
Otieno-Alego, V., Hope, G.A., Flitt, H.J. & Schweinsberg,
D.P. 1995. The corrosion of a low alloy steel in a steam turbine environment: the effect
of oxygen concentration and potential scan rate on input parameters used to
computer match the experimental polarization curves. Corrosion Science 37:
509-525.
Poursaee, A. 2010. Determining the appropriate scan rate to
perform cyclic polarization test on the steel bars in concrete. Electrochimica Acta55:
1200- 1206.
Poursae, A. & Hansson, C.M. 2009. Potential pitfalls in assessing chloride-induced corrosion of steel
in concrete. Cement and Concrete Research 39: 391-400.
Quraishi, M.A., Singh, A., Singh,
V.K., Yadav, D.K. & Singh, A.K. 2010. Green approach to corrosion inhibition of mild steel in
hydrochloric acid and sulphuric acid solutions by the
extract of Murraya koenigii leaves. Materials Chemistry and Physics 122: 114-122.
Scully, J.R., Shoesmith, D.W. & Bucheit,
R.G. 2003. Electrochemical
Technique in Corrosion Science and Engineering. New York: Marcel Deker Inc.
Zhang, X.L., Jiang, Z.H., Yao, Z.P., Song, Y.
& Wub, Z.D. 2009. Effects of scan rate on the potentiodynamic polarization curve obtained to determine
the Tafel slopes and corrosion current density. Corrosion
Science 51: 581-587.
*Corresponding author; email: insan@ukm.edu.my
|