Sains Malaysiana 44(3)(2015): 413–419
The Effect of Disinfectant Solutions on the Durability of
the Bond between Resin Based Cement and Non-precious Metal Alloy
(Kesan Disinfektan Larutan Mengenai Ketahanan daripada Ikatan
antara Resin Berasaskan Simen dan Aloi Logam Tidak Berharga)
PREMA SUKUMARAN1,2*, RICHARD FOXTON2, RON WILSON2, RICHARD MALLETT3
& MICHAEL FENLON2
1Department
of Restorative Dentistry,Faculty of Dentistry, University of Malaya
50603 Kuala Lumpur, Malaysia
2Department of
Restorative Dentistry, King’s College London Dental Institute
Guy’s Hospital, London, SE1 9RT, United Kingdom
3Department of
Biomaterials, Biomimetics and Biophotonics, King’s College London Dental
Institute, Guy’s Hospital, London, SE1 9RT, United Kingdom
Received: 25 September 2013/Accepted: 9 September 2014
ABSTRACT
This study evaluated the effect of disinfectants on the tensile
bond strength of Nickel-Chromium alloy bonded with resin cement. 180 pairs of
Nickel-Chromium dumbbells were prepared. The dumbbells were divided into 3
groups (n=60),
which received one of the following treatments: Sandblasted only (control),
sandblasted and Perform®-ID or sandblasted and sodium hypochlorite (SH)
before bonding with resin cement. All bonded specimens were stored in distilled
water for 24 h and half of the specimens were subsequently thermocycled (500
cycles) before debonding. Tensile bond strength was recorded and each dumbbell
was examined for failure mode. Two-way ANOVA analysis indicated that overall there
was a statistically significant difference between 24 h and thermocycling test,
but no differences between sandblasted only, sandblasted and Perform-ID or
sandblasted and SH groups. Post-ANOVA contrasts indicated
that only the sandblasted and SH group showed a significant difference
between the 24 h and thermocycling test. Disinfectants did not significantly
decrease tensile bond strength between Nickel-Chromium dumbbells bonded with
resin cement.
Keywords: Adhesion; alloys; cements; disinfectants
ABSTRAK
Kajian ini menilai kesan disinfektan pada kekuatan ikatan tegangan
aloi nikel-kromium yang terikat dengan simen resin. 180 pasang dumbbells nikel-kromium telah disediakan. Dumbbells kemudiannya dibahagikan kepada 3 kumpulan (n=60)
dan menerima salah satu daripada rawatan berikut: Bagas pasir sahaja
(kawalan), bagas pasir dan Perform®-ID atau bagas pasir dan natrium hipoklorit (SH)
sebelum ikatan dengan resin simen. Semua spesimen ikatan telah disimpan
dalam air suling untuk 24 jam dan separuh daripada spesimen tersebut
kemudiannya dikitar haba (500 kitaran) sebelum diikat. Kekuatan
ikatan tegangan direkod dan setiap dumbbell telah diperiksa
untuk mod kegagalan. Analisis ANOVA dua hala menunjukkan
bahawa secara keseluruhannya terdapat adalah perbezaan bererti secara
statistik antara 24 jam dan ujian pengitaran haba, tetapi perbezaan
antara bagas pasir sahaja, bagas pasir dan Perform®-ID atau bagas pasir dan
kumpulan SH.
Perbezaan Post-ANOVA menunjukkan bahawa hanya bagas pasir dan
kumpulan SH
menunjukkan perbezaan yang ketara antara 24 jam dan
ujian pengitaran haba. Disinfektan pula tidak mengurangkan kekuatan
ikatan tegangan antara dumbbells nikel-kromium yang terikat
dengan simen resin dengan ketara.
Kata kunci: Aloi; disinfektan; lekat; simen
REFERENCES
Abreu, A., Loza, M.A., Elias, A., Mukhopadhyay,
S., Looney, S. & Rueggeberg, F.A. 2009. Tensile bond strength of an
adhesive resin cement to different alloys having various surface treatments. J.
Prosthet. Dent. 101: 107-118.
ADA Council on Scientific Affairs and ADA
Council on Dental Practice. 1996. Infection control recommendations for the
dental office and the dental laboratory. J. Am. Dent. Assoc. 127:
672-680.
Ahmad, S., Tredwin, C.J., Nesbit, M. &
Moles, D.R. 2007. Effect of immersion disinfection with Perform®-ID on
alginate, an alginate alternative, an addition-cured silicone and resultant
type III gypsum casts. Br. Dent. J. 202(1): E1.
Denizoglu, S., Hanyaloglu, C.S. & Aksakal,
B. 2009. Tensile bond strength of composite luting cements to metal alloys
after various surface treatments. Indian J. Dent. Res. 20: 174-179.
Fonseca, R.G., dos Santos, J.G., Haneda, I.G.
& Adabo, G.L. 2009. Effect of metal primers on bond strength of resin
cements to base metals. J. Prosthet. Dent. 101: 262-268.
International Standardisation Organisation.
Dental Materials- Testing of adhesion to tooth structure. 2000. ISO/TC 106/ SC
1/WG 11-N1:1-7.
Kohli, S., Levine, W.A., Grisius, R.J. &
Fenster, R.K. 1990. The effect of three different surface treatments on the
tensile strength of the resin bond to nickel-chromium-beryllium alloy. J.
Prosthet. Dent. 63: 4-8.
Kohn, W.G., Collins, A.S., Cleveland, J.L.,
Harte, J.A., Eklund, K.J. & Malvitz, D.M. 2003. Guidelines for infection
control in dental health-care settings-2003. Mmwr. Morb. Mortal. Wkly. Rep. 52:
1-61.
Langenwalter, E.M., Aquilino, S.A. & Turner,
K.A. 1990. The dimensional stability of elastomeric impression materials
following disinfection. J. Prosthet. Dent. 63: 270-276.
Matsumura, H., Tanaka, T., Taira, Y. &
Atsuta, M. 1996. Bonding of cobalt chromium alloy with acidic primers and
tri-n-butylborane-initiated luting agent. J. Prosthet. Dent. 76:
194-199.
McDonnell, G. & Russell, A.D. 1999.
Antiseptics and disinfectants: Activity, action and resistance. Clin.
Microbiol. Rev. 12: 147-179.
McGowan, M.J., Shimoda, L.M. & Woolsey, G.D.
1988. Effects of sodium hypochlorite on denture base metal during immersion for
short term sterilization. J. Prosthet. Dent. 60: 212-218.
O’Hoy, P.Y., Messer, H.H. & Palamara, J.E.
2003. The effect of cleaning procedures on fracture properties and corrosion of
NiTi files. Int. Endod. J. 26: 724-732.
Pavarina, A.C.,
Pizzolitto, A.C., Machado, A.L., Vergani, C.E. & Giampaolo, E.T. 2003. An
infection control protocol: Effectiveness of immersion solutions to reduce the
microbial growth on dental prostheses. J. Oral. Rehabil. 30: 532-536.
Rentzia, A., Coleman, D.C., O’Donnell, M.J. &
O’Sullivan, M. 2011. Disinfection procedures: Their efficacy and effect on
dimensional accuracy and surface quality of an irreversible hydrocolloid
impression material. J. Dent. 39: 133-140.
Sarkar, N.K., Redmond, W., Schwaninger, B. & Goldberg,
A.J.Y. 1983. The chloride corrosion behavior of four orthodontic wires. J.
Oral. Rehabil. 10: 121-128.
Tanaka, T., Nagata, K., Takeyama, M., Atsuta, A.,
Nakabayashi, N. & Masuhara, E. 1981. 4-META Opaque resin-a new resin
strongly adhesive to nickel chromium alloy. J. Dent. Res. 60: 1697-1706.
Yoshida, K., Taira, Y., Sawase, T. & Atsuta, M. 1997.
Effects of adhesive primers on bond strength of self-curing resin to cobalt
chromium alloy. J. Prosthet. Dent. 77: 617-620.
*Corresponding
author; email: prema@um.edu.my
|