Sains Malaysiana 44(3)(2015): 413–419

 

The Effect of Disinfectant Solutions on the Durability of the Bond between Resin Based Cement and Non-precious Metal Alloy

(Kesan Disinfektan Larutan Mengenai Ketahanan daripada Ikatan antara Resin Berasaskan Simen dan Aloi Logam Tidak Berharga)

 

PREMA SUKUMARAN1,2*, RICHARD FOXTON2, RON WILSON2, RICHARD MALLETT3

& MICHAEL FENLON2

 

1Department of Restorative Dentistry,Faculty of Dentistry, University of Malaya

50603 Kuala Lumpur, Malaysia

 

2Department of Restorative Dentistry, King’s College London Dental Institute

Guy’s Hospital, London, SE1 9RT, United Kingdom

 

3Department of Biomaterials, Biomimetics and Biophotonics, King’s College London Dental Institute, Guy’s Hospital, London, SE1 9RT, United Kingdom

 

Received: 25 September 2013/Accepted: 9 September 2014

 

ABSTRACT

This study evaluated the effect of disinfectants on the tensile bond strength of Nickel-Chromium alloy bonded with resin cement. 180 pairs of Nickel-Chromium dumbbells were prepared. The dumbbells were divided into 3 groups (n=60), which received one of the following treatments: Sandblasted only (control), sandblasted and Perform®-ID or sandblasted and sodium hypochlorite (SH) before bonding with resin cement. All bonded specimens were stored in distilled water for 24 h and half of the specimens were subsequently thermocycled (500 cycles) before debonding. Tensile bond strength was recorded and each dumbbell was examined for failure mode. Two-way ANOVA analysis indicated that overall there was a statistically significant difference between 24 h and thermocycling test, but no differences between sandblasted only, sandblasted and Perform-ID or sandblasted and SH groups. Post-ANOVA contrasts indicated that only the sandblasted and SH group showed a significant difference between the 24 h and thermocycling test. Disinfectants did not significantly decrease tensile bond strength between Nickel-Chromium dumbbells bonded with resin cement.

 

Keywords: Adhesion; alloys; cements; disinfectants

 

ABSTRAK

Kajian ini menilai kesan disinfektan pada kekuatan ikatan tegangan aloi nikel-kromium yang terikat dengan simen resin. 180 pasang dumbbells nikel-kromium telah disediakan. Dumbbells kemudiannya dibahagikan kepada 3 kumpulan (n=60) dan menerima salah satu daripada rawatan berikut: Bagas pasir sahaja (kawalan), bagas pasir dan Perform®-ID atau bagas pasir dan natrium hipoklorit (SH) sebelum ikatan dengan resin simen. Semua spesimen ikatan telah disimpan dalam air suling untuk 24 jam dan separuh daripada spesimen tersebut kemudiannya dikitar haba (500 kitaran) sebelum diikat. Kekuatan ikatan tegangan direkod dan setiap dumbbell telah diperiksa untuk mod kegagalan. Analisis ANOVA dua hala menunjukkan bahawa secara keseluruhannya terdapat adalah perbezaan bererti secara statistik antara 24 jam dan ujian pengitaran haba, tetapi perbezaan antara bagas pasir sahaja, bagas pasir dan Perform®-ID atau bagas pasir dan kumpulan SH. Perbezaan Post-ANOVA menunjukkan bahawa hanya bagas pasir dan kumpulan SH menunjukkan perbezaan yang ketara antara 24 jam dan ujian pengitaran haba. Disinfektan pula tidak mengurangkan kekuatan ikatan tegangan antara dumbbells nikel-kromium yang terikat dengan simen resin dengan ketara.

 

Kata kunci: Aloi; disinfektan; lekat; simen

REFERENCES

 

Abreu, A., Loza, M.A., Elias, A., Mukhopadhyay, S., Looney, S. & Rueggeberg, F.A. 2009. Tensile bond strength of an adhesive resin cement to different alloys having various surface treatments. J. Prosthet. Dent. 101: 107-118.

ADA Council on Scientific Affairs and ADA Council on Dental Practice. 1996. Infection control recommendations for the dental office and the dental laboratory. J. Am. Dent. Assoc. 127: 672-680.

Ahmad, S., Tredwin, C.J., Nesbit, M. & Moles, D.R. 2007. Effect of immersion disinfection with Perform®-ID on alginate, an alginate alternative, an addition-cured silicone and resultant type III gypsum casts. Br. Dent. J. 202(1): E1.

Denizoglu, S., Hanyaloglu, C.S. & Aksakal, B. 2009. Tensile bond strength of composite luting cements to metal alloys after various surface treatments. Indian J. Dent. Res. 20: 174-179.

Fonseca, R.G., dos Santos, J.G., Haneda, I.G. & Adabo, G.L. 2009. Effect of metal primers on bond strength of resin cements to base metals. J. Prosthet. Dent. 101: 262-268.

International Standardisation Organisation. Dental Materials- Testing of adhesion to tooth structure. 2000. ISO/TC 106/ SC 1/WG 11-N1:1-7.

Kohli, S., Levine, W.A., Grisius, R.J. & Fenster, R.K. 1990. The effect of three different surface treatments on the tensile strength of the resin bond to nickel-chromium-beryllium alloy. J. Prosthet. Dent. 63: 4-8.

Kohn, W.G., Collins, A.S., Cleveland, J.L., Harte, J.A., Eklund, K.J. & Malvitz, D.M. 2003. Guidelines for infection control in dental health-care settings-2003. Mmwr. Morb. Mortal. Wkly. Rep. 52: 1-61.

Langenwalter, E.M., Aquilino, S.A. & Turner, K.A. 1990. The dimensional stability of elastomeric impression materials following disinfection. J. Prosthet. Dent. 63: 270-276.

Matsumura, H., Tanaka, T., Taira, Y. & Atsuta, M. 1996. Bonding of cobalt chromium alloy with acidic primers and tri-n-butylborane-initiated luting agent. J. Prosthet. Dent. 76: 194-199.

McDonnell, G. & Russell, A.D. 1999. Antiseptics and disinfectants: Activity, action and resistance. Clin. Microbiol. Rev. 12: 147-179.

McGowan, M.J., Shimoda, L.M. & Woolsey, G.D. 1988. Effects of sodium hypochlorite on denture base metal during immersion for short term sterilization. J. Prosthet. Dent. 60: 212-218.

O’Hoy, P.Y., Messer, H.H. & Palamara, J.E. 2003. The effect of cleaning procedures on fracture properties and corrosion of NiTi files. Int. Endod. J. 26: 724-732.

Pavarina, A.C., Pizzolitto, A.C., Machado, A.L., Vergani, C.E. & Giampaolo, E.T. 2003. An infection control protocol: Effectiveness of immersion solutions to reduce the microbial growth on dental prostheses. J. Oral. Rehabil. 30: 532-536.

Rentzia, A., Coleman, D.C., O’Donnell, M.J. & O’Sullivan, M. 2011. Disinfection procedures: Their efficacy and effect on dimensional accuracy and surface quality of an irreversible hydrocolloid impression material. J. Dent. 39: 133-140.

Sarkar, N.K., Redmond, W., Schwaninger, B. & Goldberg, A.J.Y. 1983. The chloride corrosion behavior of four orthodontic wires. J. Oral. Rehabil. 10: 121-128.

Tanaka, T., Nagata, K., Takeyama, M., Atsuta, A., Nakabayashi, N. & Masuhara, E. 1981. 4-META Opaque resin-a new resin strongly adhesive to nickel chromium alloy. J. Dent. Res. 60: 1697-1706.

Yoshida, K., Taira, Y., Sawase, T. & Atsuta, M. 1997. Effects of adhesive primers on bond strength of self-curing resin to cobalt chromium alloy. J. Prosthet. Dent. 77: 617-620.

 

 

*Corresponding author; email: prema@um.edu.my

 

 

previous