Sains Malaysiana 46(9)(2017): 1513–1520

http://dx.doi.org/10.17576/jsm-2017-4609-21

 

The Evaluation of Spatial Variation of Water Quality in Sungai Setiu Basin, Terengganu

(Penilaian Perubahan Reruang terhadap Kualiti Air di Lembangan Sungai Setiu, Terengganu)

 

IZYAN MUNIRAH M. ZAIDEEN1, SUHAIMI SURATMAN1 & NORHAYATI MOHD TAHIR1,2*

 

1Institute of Oceanography and Environment, Universiti Malaysia Terengganu

21030 Kuala Terengganu, Terengganu Darul Iman, Malaysia

 

2School of Marine Science and Environment, Universiti Malaysia Terengganu

21030 Kuala Terengganu, Terengganu Darul Iman, Malaysia

 

Received: 30 May 2016/Accepted: 24 April 2017

 

ABSTRACT

This study investigates the spatial variation of water quality parameters in Sungai Setiu Basin at ten different locations from March 2010 to February 2011. The water quality was assessed using the Water Quality Index by Malaysian Department of Environment (DOE-WQI) and classified according to the Malaysia Interim National Water Quality Standard (INWQS). Six water quality parameters embedded in the DOE-WQI were dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), pH, ammoniacal nitrogen (AN) and total suspended solid (TSS). In addition, this study also examined the changes in water quality over the past 10 years by comparing the present water quality to the previous works. The overall mean WQI value obtained was 84.0 which indicate that the Sungai Setiu basin is in clean condition and all measured water quality parameters gave value within the permissible limits of the INWQS classification except for pH which fall in Class III. It can be concluded that water quality in Sungai Setiu does not varies greatly over a decade. Hence continuous monitoring is needed to improve the water quality and minimize water pollution.

 

Keywords: DOE-WQI; INWQS classification; physical parameters; Sungai Setiu basin (Malaysia)

 

 

ABSTRAK

Kajian ini dijalankan untuk mengkaji variasi reruang bagi parameter kualiti air antara sepuluh lokasi yang berbeza di lembangan Sungai Setiu bermula pada Mac 2010 hingga Februari 2011. Kualiti air dinilai menggunakan Indeks Kualiti Air oleh Jabatan Alam Sekitar, Malaysia (IKA-JAS) dan dikelaskan mengikut Piawaian Interim Kualiti Air Kebangsaan, Malaysia (INWQS). Enam parameter yang digunakan dalam IKA-JAS telah dianalisis iaitu oksigen terlarut (DO), permintaan oksigen biokimia (BOD), permintaan oksigen kimia (COD), pH, ammoniakal nitrogen (AN) dan jumlah pepejal terampai (TSS). Di samping itu, kajian ini juga menentukan perubahan kualiti air sejak 10 tahun yang lalu melalui perbandingan dengan kajian yang terdahulu. Hasil kajian menunjukkan bahawa nilai purata IKA yang diperoleh adalah 84.0 dan ini menunjukkan lembangan Sungai Setiu adalah dalam keadaan bersih dan semua parameter kualiti air yang diukur telah memberikan bacaan dalam had yang dibenarkan mengikut pengklasifikasian INWQS kecuali nilai pH yang berada dalam kelas III. Dapat disimpulkan bahawa kualiti air di lembangan Sungai Setiu tidak menunjukkan perubahan yang ketara untuk tempoh sedekad. Walau bagaimanapun, pemantauan berterusan diperlukan untuk meningkatkan kualiti air dan mengurangkan pencemaran air.

 

Kata kunci: IKA-JAS; lembangan Sungai Setiu (Malaysia); parameter fizikal; pengklasifikasian INWQS

 

REFERENCES

 

Amneera, W.A., Najib, N.W.A.Z., Mohd Yusof, S.R. & Ragunathan, S. 2013. Water quality index of Perlis River, Malaysia. International Journal of Civil & Environmental Engineering 13(2): 1-6.

APHA. 2012. Standard Methods for the Examination of Water and Wastewater. Standard Methods http://doi.org/10.2105/ AJPH.51.6.940-a. p. 741.

Bharti, N. & Katyal, D. 2011. Water quality indices used for surface water vulnerability assessment. Journal of Environmental Sciences 2(1): 154-173. http://doi. org/10.6088/ijes.00202010017.

Bordalo, A.A., Teixeira, R. & Wiebe, W.J. 2006. A water quality index applied to an international shared river basin: The case of the Douro River. Environmental Management 38(6): 910- 920. http://doi.org/10.1007/s00267-004-0037-6.

Brown, R.M., McClelland, N.I., Deininger, R.A. & Tozer, R.G. 1970. A water quality index: Do we dare? Water Sewage Works 117(10): 339-343.

Fawaz Al-Badaii, Mohammad Shuhaimi-Othman & Muhd Barzani Gasim 2013. Water quality assessment of the Semenyih River. Journal of Chemistry 5: 31-34. http://doi. org/10.1155/2013/871056.

Department of Environment Malaysia (DOE). 2006. Malaysia Environmental Quality Report. Kuala Lumpur, Malaysia.

Deraman, M.Y. 2002. Penilaian kualiti air sungai setiu berdasarkan indeks kualiti air jabatan alam sekitar. Universiti Putra Malaysia Terengganu, Malaysia (Unpublished).

Grasshoff, K., Kremling, K. & Ehrhardt, M. 2007. Methods of Seawater Analysis: Third, Completely Revised and Extended Edition. http://doi.org/10.1002/9783527613984

Jessie, J.B. 2008. Water Quality Assesment of Setiu River Basin, Terengganu. Thesis. Universiti Malaysia Terengganu, Malaysia (Unpublished).

Wan Mohd Afiq, W.M.K., Abdullah, M.P., Amerudin, N.A. & Padli, N. 2013. Physicochemical analysis on water quality status of Bertam River in Cameron Highlands, Malaysia. Journal of Materials and Environmental Science 4(4): 488- 495.

Lescesen, I., Pantelic, M., Dolinaj, D., Stojanovic, V. & Milosevic, D. 2015. Statistical analysis of water quality parameters of the Drina River (West Serbia). Polish Journal of Environmental Studies 24(2): 555-561. http://doi.org/10.15244/pjoes/29684.

Lopes, J.F. & Silva, C. 2006. Temporal and spatial distribution of dissolved oxygen in the Ria de Aveiro lagoon. Ecological Modelling 197(1-2): 67-88. http://doi.org/10.1016/j. ecolmodel.2006.03.012.

Milovanovic, M. 2007. Water quality assessment and determination of pollution sources along the Axios/Vardar River, Southeastern Europe. Desalination 213(1-3): 159-173. http://doi.org/10.1016/j.desal.2006.06.022.

Naubi, I., Zardari, N.H., Shirazi, S.M., Farahen, N., Ibrahim, B. & Baloo, L. 2016. Effectiveness of water quality index for monitoring Malaysian river water quality. Pol. J. Environ. Stud. 25(1): 231-239. http://doi.org/10.15244/pjoes/60109.

Norhayati, M., Rahim, H.M., Abas, M.R. & Rashid, M.K. 2006. Distribution and characterization of hydrocarbons in sediments of Setiu Wetland, Terengganu: A preliminary study. Malaysia Journal of Analytical Sciences 10: 177-184.

Pesce, S.F. & Wunderlin, D.A. 2000. Use of water quality indices to verify the impact of Cordoba City (Argentina) on Suquia River. Water Research 34(11): 2915-2926. http://doi. org/10.1016/S0043-1354(00)00036-1.

Rosli, N., Gandaseca, S., Ismail, J. & Jailan, M.I. 2010. Comparative study of water quality at different peat swamp forest of Batang Igan, Sibu Sarawak. American Journal of Environmental Sciences 6(5): 416-421. http://doi. org/10.3844/ajessp.2010.416.421.

Suratman, S., Hussein, A.N.A.R., Tahir, N.M., Latif, M.T., Mostapa, R. & Weston, K. 2016. Seasonal and spatial variability of selected surface water quality parameters in Setiu wetland, Terengganu, Malaysia. Sains Malaysiana45(4): 551-558.

Suratman, S., Mohd Sailan, M.I., Hee, Y.Y., Bedurus, E.A. & Latif, M.T. 2015. Kajian awal indeks kualiti air di lembangan Sungai Terengganu, Malaysia. Sains Malaysiana 44(1): 67-73.

Suratman, S., Hussein, A.N.A.R., Latif, M.T. & Weston, K. 2014. Reassessment of physico-chemical water quality in Setiu Wetland, Malaysia. Sains Malaysiana43(8): 1127-1131.

Suratman, S. & Tahir, N. 2013. Kesan antropogenik terhadap kualiti air di lembangan Sungai Marang, perairan selatan Laut China Selatan. Sains Malaysiana42(6): 743-751.

Tahir, N., Suratman, S., Siti Rosnani, J., Suhairul Nizam, Y., Norashiqin, M. & Law, A. 2005. Penentuan indeks kualiti air dan nutrien terlarut di Sungai Nerus, Terengganu. Malaysian Journal of Analytical Sciences 8: 193-197.

Terrado, M., Borrell, E., Campos, S., Barceló, D. & Tauler, R. 2010. Surface water quality indices for the analysis of data generated by automated sampling networks. Trends in Analytical Chemistry 29: 40-52.

Zulfadhli, M.K. 2005. Kajian Indeks Kualiti Air di Lembangan Sungai Setiu, Terengganu. Tesis. Kolej Universiti Sains dan Teknologi Malaysia, Malaysia (Unpublished).

 

 

*Corresponding author; email: hayati@umt.edu.my

 

 

 

previous