Sains Malaysiana 48(7)(2019):
1409–1416
http://dx.doi.org/10.17576/jsm-2019-4807-09
A Hydrogen Peroxide Biosensor
from Horseradish peroxidase Immobilization onto Acrylic Microspheres
(Biosensor Hidrogen Peroksida
Berasaskan Pemegunan Peroksidase Lobak Putih pada
Mikrosfera Akrilik)
EDA YUHANA ARIFFIN1, NIK NURHANAN NIK MANSOR1, EKA SAFITRI2, LEE YOOK HENG1 & NURUL IZZATY HASSAN1*
1Centre
for Advanced Materials and Renewable Resources, Faculty of Science
and Technology, Universiti Kebangsaan Malaysia,
43600 UKM Bangi, Selangor Darul
Ehsan, Malaysia
2Department
of Chemistry, Faculty of Mathematics and Natural Sciences, Syiah
Kuala University (USK), Darussalam-Banda Acheh
23111, Indonesia
Diserahkan:
19 November 2018/Diterima: 8 April 2019
ABSTRACT
The sensitive and rapid
detection of hydrogen peroxide is very important in the areas of
clinical and environmental analyses. A sensitive and selective Horseradish
peroxidase (HRP)-hydrogen peroxide (H2O2)
biosensor was developed based on acrylic microspheres. Hydrophobic
poly(n-butyl acrylate-N-acryloxysuccinimide) [poly(nBA-NAS)]
microspheres were synthesized using photopolymerization in an emulsion
to form an enzyme immobilization matrix. The HRP enzyme was covalently immobilized
onto the acrylic microspheres via the succinimide functionality.
Field emission scanning electron microscope (FESEM) has been utilized to characterize
the screen-printed carbon paste electrode (SPE)
constructed from enzyme conjugated acrylic microspheres and gold
nanoparticles (AuNPs) composite (HRP/nBA-NAS/AuNPs/SPE).
Differential pulse voltammetry was used to assess the biosensor
performance. The linear response range of the hydrogen peroxide
biosensor obtained was from 1.0 × 10-2 to 1.0 × 10-10 M (R2 =
0.99) with the limit of detection (LOD) approximately at 1.0 ×
10-10
M. This is an improvement over many hydrogen peroxide
biosensors reported so far. Such improvement may be attributed to
the large surface area provided by the acrylic microspheres as a
matrix for immobilization of the HRP enzyme.
Keywords: Acrylic microsphere;
biosensor; Horseradish peroxidase;
hydrogen peroxide
ABSTRAK
Pengesanan hidrogen peroksida
yang sensitif dan cepat adalah sangat penting dalam bidang analisis
persekitaran dan klinikal. Biosensor hidrogen peroksida (H2O2)-peroksidase lobak putih (HRP) yang sensitif dan memilih
telah dibangunkan berasaskan mikrosfera akrilik. Mikrosfera hidrofobik
poli(n-butil akrilat-N-akriloksuksinimida)[poli(nBA-NAS)]
disintesis dengan menggunakan proses fotopempolimeran dalam bentuk
emulsi dan ia bertindak sebagai matriks pemegun enzim. Enzim HRP dipegunkan
secara kovalen pada mikrosfera akrilik melalui pengfungsian suksinimida.
Mikroskop elektron imbasan pancaran medan (FESEM)
telah digunakan bagi mencirikan elektrod karbon permukaan bercetak
(SPE)
yang dibina daripada komposit mikrosfera akrilik berkonjugat enzim
dan nanosfera emas (AuNPs) (HRP/nBA-NAS/AuNPs/SPE).
Voltametri denyutan pembezaan digunakan untuk penilaian prestasi
biosensor. Julat keupayaan linear bagi biosensor hidrogen peroksida
diperoleh daripada 1.0 × 10-2 hingga 1.0 × 10-10 M (R2 =
0.99) dengan had pengesanan (LOD) ditemui pada 1 × 10-10
M. Ini merupakan penambahbaikan berbanding biosensor
hidrogen peroksida yang telah terlebih dahulu dilaporkan. Penambahbaikan
ini mungkin ditentukan oleh luas permukaan yang besar yang disediakan
oleh mikrosfera akrilik sebagai tapak pemegunan enzim HRP.
Kata kunci: Biosensor; hidrogen peroksida; mikrosfera
akrilik; peroksidase lobak putih
RUJUKAN
Ansari,
A.A., Solanki, P.R. & Malhotra, B.D. 2009. Hydrogen peroxide sensor based
on horseradish peroxidase immobilized nanostructures cerium oxide film. Journal
of Biotechnology 142: 179-184.
Ariffin,
E.Y., Lee, Y.H., Futra, D., Tan, L.L., Karim, N.H.A., Ibrahim, N.N.N. &
Ahmad, A. 2018. An ultrasensitive hollow-silica-based biosensor for pathogenic Escherichia
coli DNA detection. Analytical and Bioanalytical Chemistry 410(9):
2363-2375.
Cao,
Z., Jiang, X., Xie, Q. & Yao, S. 2008. A third-generation hydrogen peroxide
biosensor based on horseradish peroxidase immobilized in a
tetrathiafulvalene-tetracyanoquinodimethane/multiwalled carbon nanotubes film. Biosensors
and Bioelectronics 24: 222-227.
Chen,
S., Yuan, R., Chai, Y., Xu, L., Wang, N., Li, X. & Zhang, L. 2006.
Amperometric hydrogen peroxide biosensor based on the immobilization of
horseradish peroxide (HRP) on the layer-by-layer assembly films of gold
colloidal nanoparticles and toluidine blue. Electroanalysis 18(5):
471-477.
Ciszewski,
A. & Gorski, Z. 1995. Stripping measurements of hydrogen peroxide based on
biocatalytic accumulation at a horseradish peroxidase/ferrocene/carbon paste
electrode. Electroanalysis 7(5): 495-497.
Dou,
Y., Haswell, S., Greenman, J. & Wadhawan, J. 2009. Immobilized antraquinone
for redox mediation of horseradish peroxidase for hydrogen peroxide sensing. Electrochemistry
Communications 11: 1976-1981.
Fang,
Z-H., Lu, L-M., Zhang, X-B., Li, H-B., Yang, B., Shen, G-L. & Yu, R-Q.
2011. A third-generation hydrogen peroxide biosensor based on horseradish
peroxidase immobilized in carbon nanotubes/SBA/15 film. Electroanalysis 23(10):
2415-2420.
Garjonyte,
R., Yigzaw, Y., Meskys, R., Malinauskas, A. & Gorton, L. 2001. Prussian
Blue- and lactate oxidase- based amperometric biosensor for lactic acid. Sensors
and Actuators B 79: 33-38.
Guilbault, G. & Lubrano, G.
1973. An enzyme electrode for the amperometric determination of glucose. Analytica
Chimica Acta 64: 439-455.
Hirst, N.A., Hazelwood,
L.D., Jayne, D.G. & Millner, P.A. 2013. An amperometric lactate biosensor
using H2O2 reduction via a Prussian Blue impregnated poly(ethyleneimine)surface
on screen printed carbon electrodes to detect anastomotic leak and sepsis. Sensors
and Actuators B 186: 674-680.
Lei, C., Zhang, Z., Liu,
H., Kong, J. & Deng, J. 1996. Biosensoring of hydrogen peroxidase using new
methtlene blue N incorporated in a montmorillonite-modified horseradish
peroxidase immobilization matrix as an electron shuttle. Analytica Chimica
Acta 332: 73-81.
Lei, C-X., Hu, S-Q.,
Gao, N., Shen, G-L. & Yu, R-Q. 2004. An amperometric hydrogen peroxide
biosensor based on immobilizing horseradish peroxidase to a nano-Au monolayer
supported by sol-gel derived carbon ceramic electrode. Bioelectrochemistry 65:
33-39.
Lin, X-Q., Chen, J.
& Chen, Z-H. 2000. Amperometric biosensor for hydrogen peroxide based on
immobilization of horseradish peroxidase on methylene blue modified graphite
electrode. Electroanalysis 12(4): 306-310.
Radi, A-E., Lates, V.
& Marty, J-L. 2008. Mediatorless hydrogen peroxide biosensor based on
horseradish peroxidase immobilized on 4-carboxyphenyl film electrografted on
gold electrode. Electroanalysis 20(23): 2557-2562.
Ricci, F., Amine, A.,
Palleschi, G. & Moscone, D. 2003. Prussian Blue based screen printed
biosensors with improved characteristics of long-term lifetime and pH
stability. Biosensors and Bioelectronics 18: 165-174.
Senel, M., Cevik, E.
& Abasiyanik, M.F. 2010. Amperometric hydrogen peroxide biosensor based on
covalent immobilization of horseradish peroxidase on ferrocene containing
polymeric mediator. Sensors and Actuators B 145: 444-450.
Shourian, M. &
Ghourchian, H. 2010. Biosensing improvement of horseradish peroxidase towards
hydrogen peroxide upon modifying the accessible lysines. Sensors and
Actuators B 145: 607-612.
Ulianas, A., Nurlely,
Y., Lee, Y.H. & Tan, L.L. 2018. Synthesis and optimization of acrylic
N-acryloxysuccinimide copolymer microspheres. International Journal on Advanced
Science 8(3): 780-784.
Ulianas, A., Lee, Y.H.,
Ahmad, M., Lau, H.Y., Ishak, Z. & Tan, L.L. 2014. A regenerable
screen-printed DNA biosensor based on acrylic microsphere-gold nanoparticle
composite for genetically modified soybean determination. Sensors and
Actuators B 190: 694-701.
Ulianas, A., Lee, Y.H.,
Hanifah, S.A. & Tan, L.L. 2012. An electrochemical DNA microbiosensor based
on succinimide-modified acrylic microspheres. Sensors 12(5): 5445-5460.
Ulianas, A., Lee, Y.H.
& Ahmad, M. 2011. A biosensor for urea from succinimide-modified acrylic
microspheres based on reflectance transduction. Sensors 11(9):
8323-8338.
Villalonga, R., Diez,
P., Yanez-Sedeno, P. & Pingarron, J.M. 2011. Wiring horseradish peroxidase
on gold nanoparticles-based nanostructured polymeric network for the
construction of mediatorless hydrogen peroxide biosensor. Electrochimica
Acta 56: 4672-4677.
Wang, J. 2001. Glucose
biosensors: 40 years of advances and challenges. Electroanalysis 12:
983-988.
Wang, L. & Wang, E.
2004. A novel hydrogen peroxide sensor based on horseradish peroxidase
immobilized on colloidal Au modified ITO electrode. Electrochemistry
Communications 6: 225-229.
Xu, J-J., Zhou, D-M.
& Chen, H-Y. 1998. A reagentless hydrogen peroxide biosensor based on the
coimmobilization of thionine and horseradish peroxidase by their cross-linking
with glutaraldehyde on glassy carbon electrode. Electroanalysis 10(10):
713-716.
Yu, D., Blankert, B.,
Bodoki, E., Bollo, S., Vir’e, J-C., Sandulescu, R., Nomura, A. & Kauffmann,
J-M. 2006. Amperometric biosensor based on horseradish peroxidase-immobilised
magnetic microparticles. Sensors and Actuators B 133: 749-754.
Zhang, Y.L., Jin, S-Z.,
Zhang, C-X. & Shen, H-X. 2001. Studies on electrocatalytical kinetic
behaviour of horseradish peroxide and assay for hydrogen peroxide at salt
bridge supported bilayer lipid membrane. Electroanalysis 13(2): 137-142.
Zhang, D., Zhao, H.,
Fan, Z., Li, M., Du, P., Liu, C., Li, Y., Li, H. & Cao, H. 2015. A highly
sensitive and selective hydrogen peroxide biosensor based on gold nanoparticles
and three-dimensional porous carbonized chicken eggshell membrane. PLoS ONE 10(6):
e0130156.
*Pengarang
untuk surat-menyurat; email: drizz@ukm.edu.my
|