Sains Malaysiana 49(11)(2020): 2785-2791

http://dx.doi.org/10.17576/jsm-2020-4911-17

 

Eye Blinking Patterns, Corneal Staining and Compliance in a Group of Soft Contact Lens Wearers

(Corak Kerdipan Mata, Pewarnaan Kornea dan Komplians pada Satu Kumpulan Pemakai Kanta Sentuh)

 

BASHIRAH ISHAK1*, NUR SAKINAH SAAD1, LIM SIEW LEE1, NORLAILA MAT DAUD1, BARIAH MOHD ALI1 & NORHANI MOHIDIN2

 

1Optometry & Vision Sciences Programme, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, 50300 Kuala Lumpur, Wilayah Persekutuan, Malaysia

 

2School of Optometry, Universiti Teknologi MARA, 42300 Bandar Puncak Alam, Selangor Darul Ehsan, Malaysia

 

Received: 26 August 2019/Accepted: 17 May 2020

 

ABSTRACT

Many factors influence the success of contact lens wear, including lens surface moisture, which is affected by blinking. This study was conducted to determine the eye blinking patterns, corneal staining, and compliance in a group of soft contact lens (CL) wearers. Forty-one soft CL wearers and 41 age-matched control subjects (non-CL wearers) were recruited in this study. Blinking patterns were assessed with a digital camera attached to a slit lamp biomicroscope. Corneal staining was graded using Institute for Eye Research (IER) grading scale with 0.1 increments. The subject’s compliance level was determined using a questionnaire. There was no difference in eye blinking patterns between the CL wearers and control group (Mann-Whitney, p = 0.231). The average grades of corneal staining in CL wearers and control group were 0.38 ± 0.39 and 0.01 ± 0.08 unit, respectively. There was a significant difference in corneal staining between the two groups (Mann-Whitney, p = 0.021). A significant positive correlation was found between blinking patterns and corneal staining (Spearman ρ = 0.378, p = 0.015). Our results also showed that 63.4% of the CL wearers had good compliance towards lens care. In our multiple linear regression analysis, blinking patterns contributed significantly to corneal staining (B = 0.140, p = 0.015), while compliance level did not (B = -0.038, p = 0.471). Overall, eye blinking patterns in CL wearers influenced the risk of corneal staining.

 

Keywords: Blinking pattern; compliance; corneal staining; soft contact lens

 

ABSTRAK

Terdapat banyak faktor mempengaruhi kejayaan pemakaian kanta sentuh, termasuklah kelembapan permukaan kanta yang dipengaruhi oleh kerdipan mata. Kajian ini dijalankan untuk menentukan corak kerdipan mata, pewarnaan kornea dan komplians pada satu kumpulan pemakai kanta sentuh (KS). Empat puluh satu pemakai KS lembut dan 41 subjek kawalan (bukan pemakai KS) dengan umur yang sama direkrut untuk kajian ini. Corak kerdipan dinilai dengan kamera digital yang dilekatkan pada lampu celah biomikroskop. Pewarnaan kornea digred menggunakan skala penggredan Institute for Eye Research (IER) dengan kenaikan 0.1. Tahap komplians subjek ditentukan dengan menggunakan soal selidik. Didapati tiada perbezaan pada corak kerdipan mata antara pemakai KS dan kumpulan kawalan (Mann-Whitney, p = 0.231). Gred purata pewarnaan kornea pemakai KS dan kumpulan kawalan adalah 0.38 ± 0.39 dan 0.01 ± 0.08 unit. Terdapat perbezaan signifikan pada pewarnaan kornea antara kedua-dua kumpulan (Mann-Whitney, p = 0.021). Terdapat korelasi positif signifikan antara corak kerdipan dan pewarnaan kornea (Spearman ρ = 0.378, p = 0.015). Keputusan kajian juga menunjukkan 63.4% pemakai KS mempunyai komplians yang baik terhadap penjagaan kanta. Melalui analisis regresi linear berganda, didapati corak kerdipan mata menyumbang secara signifikan kepada pewarnaan kornea (B = 0.140, p = 0.015) manakala tahap komplians tidak (B = -0.038, p = 0.471).

 

Keseluruhannya, corak kerdipan mata pemakai KS mempengaruhi risiko terhadap pewarnaan kornea.

Kata kunci: Corak kerdipan; kanta sentuh lembut; komplians; pewarnaan kornea

 

REFERENCES

Abelson, M.B. & Holly, F.J. 1977. A tentative mechanism for inferior punctuate keratopathy. American Journal of Ophthalmology 83(6): 866-869.

Begley, C.G., Barr, J.T., Edrington, T.B., Long, W.D., McKenney, C.D. & Chalmers, R.L. 1996. Characteristics of corneal staining in hydrogel contact lens wearers. Optometry and Vision Science 73(3): 193-200.

Bergmanson, J. 2006. Interpretation of corneal staining on your patient and in the literature. Nordic Vison 6: 8-9.

Bhandari, M. & Hung, P.R. 2012. Habits of contact lens wearers toward lens care in Malaysia. The Medical Journal of Malaysia 67(3): 274-277.

Bowden, F.W., Cohen, E.J. & Arentsen, J.J. 1989. Patterns of lens care practices and lens product contamination in contact lens associated microbial keratitis. Contact Lens Association of Ophthalmologists 15(1): 49-54.

Bui, T.H., Cavanagh, H.D. & Robertson, D.M. 2010. Patient compliance during contact lens wear: Perception, awareness and behavior. Eye Contact Lens 36(6): 334-339.

Carney, R.G. & Hill, R.M. 1984. Variation in blinking behavior during soft lens wear. International Contact Lens Clinic 11(4): 250-253.

Claydon, B.E. & Efron, N. 1994. Non-compliance in contact lens wear. Ophthalmic and Physiological Optics 14(4): 356-364.

Collins, M.J. & Carney, L.G. 1986. Compliance with care and maintenance procedures   amongst contact lens wearers. Clin. and Experimental Optometry 69(5): 174-177.

Collins, M.J., Iskander, D.R., Saunders, A., Hook, S., Anthony, E. & Gillon, R. 2006. Blinking patterns and corneal staining. Eye Contact Lens 32(6): 287-293.

Collins, M.J., Seeto, R., Campbell, L. & Ross, M. 1989. Blinking and corneal sensitivity. Acta Ophthalmology 67(5): 525-531.

Davidson, S.I. & Akingbehin, T. 1980. Compliance in ophthalmology. Transactions of the Ophthalmological Societies of the United Kingdom 100(Pt2): 286-290.

Dundas, M., Walker, A. & Woods, R. 2001. Clinical grading of corneal staining of non-contact lens wearers. Ophthalmic and Physiological Optics 21(1): 30-35.

Efron, N. & Fitzgerald, J.P. 1996. Distribution of oxygen across the surface of the human cornea during soft contact lens wear. Optometry and Vision Science 73(10): 659-665.

Guillon, J.P., Guillon, M. & Malgouyres, S. 1990. Corneal desiccation staining with hydrogel lenses: Tear film and contact lens factors. Ophthalmology and Physiological Optics 10(4): 343-350.

Hamano, H., Kitano, J., Mitsunaga, S., Kojima, S. & Kissling, G.E. 1985. Adverse effects of contact lens wear in a large Japanese population. Contact Lens Association of Ophthalmologists 11(2): 141-147.

Hart, W.M. 1992. Adler’s Physiology of the Eye: The Eyelids. St. Louis: Mosby.

Himebaugh, N.L., Begley, C.G., Bradley, A. & Wilkinson, J.A. 2009. Blinking and tear break-up during four visual tasks. Optometry and Vision Science 86(2): E106-E114.

Ishak, B., Thye, J.J.Y., Mohd-Ali, B. & Mohidin, N. 2012. Blinking characteristics and corneal staining in different soft lens materials. World Academy of Science, Engineering and Technology 72: 1661-1665.

Jalbert, I., Sweeney, D.F. & Holden, B.A. 1999. The characteristics of corneal staining in successful daily and extended disposable contact lens wearers. Clinical Experimental Optometry 82(1): 4-10.

Kikkawa, D.O., Lucarelli, M.J., Shovlin, J.P., Briggs, E., Cook, J. & Lemke, B.N. 2003. Adler’s Physiology of the Eye: Opthalmic Facial Anatomy and Physiology. St Louis: Mosby.

Kwon, K.A., Shipley, R.J., Edirisingre, M., Ezra, D.G., Rose, G., Best, S.M. & Cameron, R.E. 2013. High-speed camera characterization of voluntary eye blinking kinematics. Journal of The Royal Society Interface10(85): 20130227.

Mohidin, N. & Zulkipli, N.N. 2019. Tears stability, corneal staining and dry eye symptoms in contact lens wearers. Jurnal Sains Kesihatan Malaysia 17(2): 35-41.

Nichols, J.J. & Sinnott, L.T. 2011. Tear film, contact lens, and patient factors associated with corneal staining. Investigative of Ophthalmology Vision Science 52(2): 1127-1137.

Nichols, K.K., Mitchell, G.L., Simon, K.M., Chivers, D.A. & Edrington, T.B. 2002. Corneal staining in hydrogel lens wearers. Optometry and Vision Science 52(2): 20-30.

Stapleton, F., Keay, L., Edwards, K., Naduvilath, T., Dart, J.K., Brian, G. & Holden, B.A. 2008. The incidence of contact lens-related microbial keratitis in Australia. Ophthalmology 115(10): 1655-1662.

Tabery, H.M. 1997. Micropunctate fluorescein staining of the human corneal surface: Microerosions or cystic spaces? Acta Ophthalmology 75(2): 134-136.

Tajunisah, I., Reddy, S.C. & Phuah, S.J. 2008. Knowledge and practice of contact lens wear and care among medical students of University of Malaya. The Medical Journal of Malaysia 63(3): 207-210.

Teenan, D.W. & Beck, L. 2001. Contact lens-associated chemical burn. Contact Lens Anterior Eye 24(4): 175-176.

Weisbarth, R.E. & Henderson, B. 2005. Hydrogel lens care regimens and patient education. Clinical Contact Lens Practice 19: 381-419.

Van Der Worp, E., De Brabander, J., Swarbrick, H. & Hendrikse, F. 2008. Eyeblink frequency and type in relation to 3- and 9-o’clock staining and gas permeable contact lens variables. Optometry and Vision Science 85(9): E857-E866.

Woods, J., Varikooty, J., Fonn, D. & Jones, L.W. 2018. A novel scale for describing corneal staining. Clinical Ophthalmology 12: 2369-2375.

 

*Corresponding author; email: bashirah@ukm.edu.my

   

 

 

 

previous