Sains Malaysiana 49(4)(2020): 817-824
http://dx.doi.org/10.17576/jsm-2020-4904-11
In vivo Slit Scanning Confocal Microscopic Observation in a Patient with Keratoconus
Wearing Miniscleral Contact Lens for One Year: A Case Report
(Pemerhatian Pengimbas Celah Konfokus Mikroskop secara in vivo pada Pesakit dengan Keratokonus menggunakan Kanta Lekap Sklera Mini untuk Satu Tahun: Suatu Laporan Kes)
SOMNATH GHOSH1, HALIZA
ABDUL MUTALIB2*, SHARANJEET KAUR2 & RITUPARNA GHOSHAL2
1Department of Allied Health Sciences, Brainware
University, Barasat, Kolkata -700125, West Bengal, India
2Optometry and Vision Science Program, Faculty of
Health Sciences, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, 50300 Kuala Lumpur, Federal
Territory, Malaysia
Diserahkan: 25 Oktober 2018/Diterima: 6 Disember 2019
Abstract
The purpose of the present
case report was to evaluate corneal microstructure in a patient with
keratoconus wearing miniscleral contact lens (MS CL) for 1 year. A 38
years old patient diagnosed with stage III keratoconus in right eye and corneal
graft (penetrating keratoplasty) in left eye was referred to optometry department of a public hospital in Malaysia. Based on the MS CLs
fitting performance on the patient’s eye, MS CLs were
prescribed in both eyes. However, patient opted for MS CL only in the
right eye. In vivo slit
scanning confocal microscopy was performed at baseline
and after 1 year of contact lens wear in right eye. Qualitative analysis was done using a grading scale designed by Hollingsworth et
al. (2005a), while quantitative
analysis was performed using NAVIS software in a fixed frame of 0.06 mm². After
1 year of MS CL wear, qualitative observation of right cornea showed no
change in stromal haze and architecture of nerve fibers. However, morphological
alterations like dark bands were observed both in
anterior and posterior stroma along with tendency of clustering keratocyte
nuclei in posterior stroma. Quantitative analysis
showed that anterior and posterior stroma keratocyte density and endothelium
cell density were relatively low after 1 year of MS CL wear (817.3, 667.2, and 2577
cells/mm², respectively) caompared to baseline
observation (850.7, 705.0, and 2666 cells/mm², respectively).
Mean cell area of anterior stroma, posterior stroma and endothelium were also
different in post MS CL wear. Polymegathism and pleomorphism calculated by
NAVIS software were varied after 1 year (49.6% and
37.5%, respectively) compared to baseline (67.1% and 29.6%, respectively). In
the discussed case, noticeable changes were observed in corneal microstructure after 1 year of MS CL wear. Thereby, in conclusion we
recommend future studies with more number of keratoconic eyes wearing MS CLs to
emphasize the findings on microstructural changes in keratoconic cornea wearing
MS CLs.
Keywords: Confocal microscope; corneal microstructure; keratoconus; miniscleral lens
Abstrak
Laporan kes ini adalah bertujuan untuk mengkaji struktur
mikro kornea pesakit keratokonus yang memakai kanta lekap sklera mini (MS CL)
selama 1 tahun. Seorang pesakit berumur 38 tahun telah didiagnos dengan keratokonus tahap III pada mata kanan dan graf
kornea (penetrating
keratoplasty) pada mata kiri telah dirujuk ke Jabatan Optometri di
hospital awam di Malaysia. Berdasarkan prestasi MS CL di atas mata pesakit
beliau telah dipakaikan dengan MS CL pada kedua dua matanya. Walau bagaimanapun, pesakit memilih untuk
memakai MS CL hanya pada mata kanan sahaja. Pengimbas celah konfokus mikroskop in vivo telah dijalankan
pada garis dasar dan selepas setahun memakai kanta lekap pada mata kanan.
Analisis kualitatif telah dilakukan dengan menggunakan skala
penggredan rekaan Hollingsworth et al. (2005a), sementara analisis kuantitatif dilakukan
dengan menggunakan perisian NAVIS yang menggunakan bingkai tetap 0.06 mm².
Selepas 1 tahun memakai MS CL, kornea kanan secara kualitatif menunjukkan tiada
perubahan pada kekabutan stroma, lapisan Bowman dan rangkaian corak saraf.
Walau bagaimanapun, perubahan morfologi
seperti jalur gelap telah kelihatan di anterior dan posterior stroma bersama
dengan pengumpalan nukleus keratosit di posterior stroma. Analisis kuantitatif menunjukkan keamatan keratosit di stroma anterior dan
posterior dan sel endotelium adalah rendah secara relatif selepas setahun
pemakaian MS CL (817.3, 667.2 dan 2577 sel/mm²)
berbanding dengan nilai garis dasar (850.7, 705.0 dan 2666 sel/mm²). Luas sel
purata stroma anterior, stroma posterior dan endotelium didapati berbeza
selepas pemakaian MS CL. Polimegatisme dan pleomorfisme dihitung menggunakan perisian NAVIS
selepas 1 tahun (49.6% dan 37.5%) menunjukkan penurunan berbanding dengan garis
datar (67.1% dan 29.6%). Seperti yang dibincangkan, perubahan ketara didapati pada struktur
mikro kornea selepas setahun pemakaian MS CL. Sebagai kesimpulannya kami
mengesyorkan kajian lanjut dengan mengambil lebih banyak
mata keratokonus untuk dipasang dengan MS CL dan ini boleh menguatkan hasil
penemuan perubahan struktur mikro mata keratokonus.
Kata kunci: Kanta sklera mini; keratokonus; konfokus mikroskop; struktur mikro kornea
RUJUKAN
Alio, J.L. & Shabeyek, M.H. 2006. Corneal higher
order aberrations: A method to grade keratoconus. J. Refract. Surg. 22(6): 539-545.
Bitirgen, G., Ozkagnici, A., Bozkurt, B. & Malik,
R.A. 2015. In vivo corneal confocal
microscopic analysis in patients with keratoconus. Int. J. Ophthalmol. 8(3): 534-539.
Bitirgen, G., Ozkagnici, A.,
Malik, R.A. & Oltulu, R. 2013. Evaluation of contact lens-induced changes
in keratoconic corneas using in vivo confocal microscopy. Invest. Ophthalmol. Vis. Sci. 54(8): 5385-5391.
Bureau, J., Fabre, E.J., Hecquet, C., Pouliquen, Y.
& Lorans, G. 1993. Modification of prostaglandin E2 and collagen synthesis
in keratoconus fibroblasts, associated with an increase of interleukin 1 alpha receptor number. CR Acad. Sci. III. 316(4): 425-430.
Edmonds, C.R., Wung, S.F., Husz, M.J. & Pemberton,
B. 2004. Corneal endothelial cell count in keratoconus patients after contact
lens wear. Eye Contact Lens 30(1):
54-58.
Efron, N. 2007. Contact lens-induced changes in the
anterior eye as observed in vivo with
the confocal microscope. Prog. Retin. Eye
Res. 26(4): 398-436.
Efron, N. & Hollingsworth,
J.G. 2008. New perspectives on keratoconus as revealed by
corneal confocal microscopy. Clin. Exp. Optom. 91(1): 34-55.
Efron, N., Mutalib, H.A., Perez-Gomez, I. & Koh,
H.H. 2002. Confocal microscopic observations of the human cornea following
overnight contact lens wear. Clin. Exp.
Optom. 85(3): 149-155.
Erie, J.C., Patel, S.V.,
McLaren, J.W., Nau, C.B., Hodge, D.O. & Bourne, W.M. 2002.
Keratocyte density in keratoconus. A confocal microscopy study(a). Am. J. Ophthalmol. 134(5): 689-695.
Ghosh, S., Mutalib, H.A., Sharanjeet, K., Ghoshal, R.
& Retnasabapathy, S. 2017a.
Effects of contact lens wearing on keratoconus: A confocal microscopy
observation. Int. J. Ophthalmol. 10(2): 228-234.
Ghosh, S., Mutalib, H.A., Kaur, S., Ghoshal, R. &
Retnasabapathy, S. 2017b.
Corneal cell morphology in keratoconus: A confocal microscopic observation. Malaysian
Journal of Medical Sciences 24(2): 44-54.
Hollingsworth, J.G. &
Efron, N. 2005. Observations of banding patterns (Vogtstriae) in keratoconus: A
confocal microscopy study. Cornea 24:
162-166.
Hollingsworth, J.G., Bonshek,
R.E. & Efron, N. 2005a. Correlation of the appearance
of the keratoconic cornea in vivo by
confocal microscopy and light microscopy. Cornea 24: 397-405.
Hollingsworth,
J.G., Efron, N. & Tullo, A.B. 2005b. In
vivo corneal confocal microscopy in keratoconus. Ophthalmic.
Physiol. Opt. 25: 254-260.
Hayes, S., Boote, C., Tuft, S.J., Quantock, A.J. &
Meek, K.M. 2007. A study of corneal thickness, shape and collagen organisation
in keratoconus using videokeratography and X-ray scattering techniques. Exp. Eye Res. 84(3): 423-434.
Jhanji, V., Sharma, N. & Vajpayee, R.B. 2011.
Management of keratoconus: Current scenario. Br. J. Ophthalmol. 95(8): 1044-1050.
Kaldawy, R.M., Wagner, J., Ching, S. & Seigel,
G.M. 2002. Evidence of apoptotic cell death in keratoconus. Cornea 21(2): 206-209.
Krumeich, J.H., Daniel, J. & Knülle, A. 1998.
Live-epikeratophakia for keratoconus. J.
Cataract. Refract. Surg. 24(4): 456-463.
Mountford, J. 2011. KATT Fitting Instructions. http://capcl.com.au/custom-rgp-designs/).
Rabinowitz, Y.S. 1998.
Keratoconus. Surv. Ophthalmol. 42(4): 297-319.
Radaie-Moghadam, S., Hashemi, H., Jafarzadehpur, E.,
Yekta, A.A. & Khabazkhoob, M. 2016. Corneal biomechanical changes following
toric soft contact lens wear. J. Ophthalmic. Vis. Res. 11(2): 131-135.
Romero-Jimenez, M.,
Santodomingo-Rubido, J. & Wolffsohn, J.S. 2010. Keratoconus:
A review. Cont. Lens Anterior Eye 33(4): 157-166.
Sawaguchi,
S., Fukuchi, T., Abe, H., Kaiya, T., Sugar, J. & Yue, B.Y. 1998. Three-dimensional scanning electron microscopic
study of keratoconus corneas. Archives of Ophthalmology 116(1): 62-68.
Sihota, R., Sharma, N., Panda,
A., Aggarwal, H.C. & Singh, R. 1998. Post-penetrating keratoplasty
glaucoma: Risk factors, management and visual outcome. Aust. NZJ Ophthalmol.
26(4): 305-309.
Somodi, S., Hahnel, C.,
Slowik, C., Richter, A., Weiss, D.G. & Guthoff, R. 1996. Confocal in vivo microscopy and confocal
laser-scanning fluorescence microscopy in keratoconus. Ger. J. Ophthalmol. 5(6): 518-525.
Ucakhan, O.O., Kanpolat, A.,
Ylmaz, N. & Ozkan, M. 2006. In vivo confocal microscopy
findings in keratoconus. Eye Contact Lens 32(4): 183-191.
Weed, K.H., MacEwen, C.J.,
Cox, A. & McGhee, C.N. 2007. Quantitative analysis
of corneal microstructure in keratoconus utilising in vivo confocal microscopy. Eye (Lond). 21(5): 614-623.
Wilson, S.E., He, Y.G., Weng,
J., Li, Q., McDowall, A.W., Vital, M. & Chwang, E.L. 1996. Epithelial
injury induces keratocyte apoptosis: Hypothesized role for the interleukin-1
system in the modulation of corneal tissue organization and wound healing. Exp.
Eye Res. 62(4): 325-327.
Yeniad, B., Yilmaz, S. &
Bilgin, L.K. 2010. Evaluation of the microstructure of cornea
by in vivo confocal microscopy in
contact lens wearing and non-contact lens wearing keratoconus patients. Cont.
Lens Anterior Eye 33(4): 167-170.
*Pengarang untuk surat-menyurat; email:
haliza@ukm.edu.my
|